4W Series Fire Alarm System

     FEATURES:

  • Complete Digital solid state type.
  • Single 4 core looping for all the zones / floors. There fore
    it reduces appx. 80% cable cost.
  • Each zone can be denoted as a floor for low / high rise building.
  • Dual tone Hooter & Manual call point can be connected
    in each zone / floor.
  • Seven segment Digital display provided to show zone /
    floor numbers.
  • System programmed in that manner, If the FIRE detect on lower as well as on higher floor
    at a time. The system will give more priority to display the number of higher floor.
  • Two stage general alarm.
  • Intermittent tone for FIRE.
  • Single tone for FAULT.
  • System ON status indicator.
  • Zonal line monitoring and cable fault indicator.
  • Common FIRE flashing display.
  • Auto CALL ALL facility to all the zones / floor, If not attended the system within the preset
    time in case of FIRE.
  • Manual CALL ALL and test facility for all the zones / floors.
  • System RESET and alarm ACCEPT facility.
  • Facility to connect standby supply or battery backup.
  • Audio and visual alarm for all the signals which are being monitored by control panel.
  • Facility to shut-down auxillary units in case of FIRE (optional).
  • Automatic changeover from AC mains supply to standby supply in case of AC mains fail.
  • Automatic battery charging facility for battery backup.
  • AC and DC fuse protection.
  • Compact size of control panel.
  • Wall / concealed mounting type cabinet.
  • Membrane type key-board with key-lock facility.
  • Provision to connect Fire Repeater of 4W series.
  • Reliable system in low cost, compare to other types of fire alarm control panel.
SPECIFICATION
MECHANICAL SPECIFICATION
  • MATERIAL
  • : 18 SWG CRCA, Sheet Metal.
  • DIMENSION
  • : 240MM x 300MM x 90MM ( W x H x D )
    Dimension up to 30 Zones / Floor panel.
  • MOUNTING
  • : Wall mounting, Top cable entry.
  • WEIGHT
  • : 5.5Kg
    ELECTRICAL SPECIFICATION
  • WORKING VOLTAGE
  • : 240VAC + - 10% (Mains Supply)
  • POWER CONSUMPTION
  • : 25 Watts in quiescent condition.
    LOOP CURRENT
  • In Normal Condition
  • : 2.5 mA/Per Zone
  • In FIRE Condition
  • : 60 mA per zone with alarm
  • Potential free Fire relay
  • : 1 C/O 230VAC, 2Amp. (optional)
  • Common Fire Hooter O/P for External
        Hooter
  • : 24VDC, 250 mA ( optional)